Cookie Consent by Free Privacy Policy website

Converter S215 -5 +5 Volt


Download PDF

S215 Board for load cell


Zoom Click to enlarge image

Converter S215 -5 +5 Volt Converter S215 -5 +5 Volt Schema

Technical Specifications

Board power supply24Vcc +-15%
Cell power supply4 V dc per cell (1 cell of 350 Ω or 700 Ω) protected against short circuit
Power assumption0.6W with 350 Ohm cell
Output0 to +5V (-5/+5V) with load ≥ 2 kW
Input sensitivityStandard 2 mV/V, 1mV/V R3: 50 Ω
Dimensions45mm x 20.5mm x 10mm
ConnectionsWelded wires
Cell connectionWith 4 wires
Storage temperature- 10 °C / + 50 °C (14 °F / 122 °F)
Operating temperature- 20 °C / + 60 °C (- 4 °F / 140 °F)
Linearity0.02%
Thermal stability30 ppm/°C
Zero adjustment± 10% full scale through multi-turn trimmer
Gain adjustment±10% of full scale using multi-turn trimmer
Analog Filter100 Hz
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means